Influence of transmucosal height in abutments of single and multiple implant-supported prostheses: a non-linear three-dimensional finite element analysis

The aim of this study was to analyze the influence of three different transmucosal heights of the abutments in single and multiple implant-supported prostheses through the finite element method. External hexagon implants, MicroUnit, and EsthetiCone abutments were scanned and placed in an edentulous...

Ful tanımlama

Kaydedildi:
Detaylı Bibliyografya
Diğer Yazarlar: Borie, Eduardo (coautor), Leal, Eduardo (coautor), Orsi, Lara Augusta (coautor), Salamanca, Carlos (coautor), Dias, Fernando José (coautor), Weber, Benjamin (coautor)
Materyal Türü: Ekitap
Dil:İngilizce
Konular:
Online Erişim:https://repositoriobiblio.unach.cl/handle/123456789/1038
Etiketler: Etiketle
Etiket eklenmemiş, İlk siz ekleyin!

MARC

LEADER 00000nam a22000005a 4500
001 2-2018
003 CL-ChUAC
005 20250113160742.0
006 m o d |
007 cr cn|||||||||
008 210329s2018 xxu|||||s|||| 000 ||eng d
022 |a 1025-5842 
040 |a CL-ChUAC  |b spa  |c CL-ChUAC 
041 |a eng  |b eng  |f eng 
245 1 0 |a Influence of transmucosal height in abutments of single and multiple implant-supported prostheses: a non-linear three-dimensional finite element analysis  |c Eduardo Borie ; Eduardo Leal ; Iara Augusta Orsi ; Carlos Salamanca ; Fernando José Dias ; Benjamin Weber  
336 |2 rdacontent  |a text  |b txt 
337 |2 rdamedia  |a unmediated  |b n 
338 |2 rdacarrier   |a volume  |b nc 
520 3 |a The aim of this study was to analyze the influence of three different transmucosal heights of the abutments in single and multiple implant-supported prostheses through the finite element method. External hexagon implants, MicroUnit, and EsthetiCone abutments were scanned and placed in an edentulous maxillary model obtained from a tomography database. The simulations were divided into two groups: (1) one implant with 3.75 × 10 mm placed in the upper central incisor, simulating a single implant-supported fixed prosthesis with an EsthetiCone abutment; and (2) two implants with 3.75 × 10 mm placed in the upper lateral incisors with MicroUnit abutments, simulating a multiple implant-supported prosthesis. Subsequently, each group was subdivided into three models according to the transmucosal height (1, 2, and 3 mm). A static oblique load at an angle of 45 degrees to the long axis of the implant in palatal-buccal direction of 150 and 75 N was applied for multiple and single implant-supported prosthesis, respectively. The implants and abutments were assessed according to the equivalent Von Mises stress analyses while the bone and ceramics were analyzed through maximum and minimum principal stresses. The total deformation values increased in all models, while the transmucosal height was augmented. The transmucosal height of the abutments influences the stress values at the bone, ceramics, implants, and abutments of both the single and multiple implant-supported prostheses, with the transmucosal height of 1 mm showing the lowest stress values. 
650 4 |a Dental abutments 
650 4 |a dental implants 
650 4 |a dental stress analyses 
650 4 |a finite element analysis 
650 4 |a implant-supported dental prosthesis 
700 1 |a Borie, Eduardo  |e coautor 
700 1 |a Leal, Eduardo  |e coautor 
700 1 |a Orsi, Lara Augusta   |e coautor 
700 1 |a Salamanca, Carlos  |e coautor 
700 1 |a Dias, Fernando José   |e coautor 
700 1 |a Weber, Benjamin   |e coautor 
773 0 |d Thames, Oxfordshire United Kingdom  |g Volume 21, 2018 - Issue 1  |t Métodos informáticos en biomecánica e ingeniería biomédica [artículo de revista] 
856 4 1 |u https://repositoriobiblio.unach.cl/handle/123456789/1038 
942 |2 ddc  |c AREV 